content loaded
KIDDE 3809000119 Image 1

KIDDE 900-0119 COMBO SMOKE & CO ALARM TALK HRDWR W/BATT B/U

MFR Part #: 3809000119
SKU #: 1020756
Brand: Kidde®
UPC: 0047871001194
Please note this item is discontinued (order fulfillment will depend on stock availability): Kidde® 3809000119 1-Button Combination Multi-Function Talking Smoke and Carbon Monoxide Alarm, 10 ft Detection, Electrochemical/Ionization Sensor, (2) AA Batteries, 85 dB at 10 ft
10 Years Limited
cUL Listed | CSA-6.19-01

Kidde® Talking Smoke and Carbon Monoxide Alarm, 1-Button Combination Multi-Function, (2) AA Batteries Power Source, 10 ft Detection, Electrochemical/Ionization Sensor, 24 Kidde® Devices Interconnection, 85 dB at 10 ft Alert, Fire/Warning Carbon Monoxide/Low Battery Visual Alert, 10 to 95 % Humidity, 2 Sensors, Quick-Connect Plug with 6 in Pigtail Wiring, 40 to 100 deg F Operating, 12.3 cm Dia x 3.2 cm D Dimensions

The Kidde® KN-COSM-IBACA uses breakthrough technology to offer a fast response to real fires, including smoldering and fast flaming, as well as protect you from carbon monoxide and dramatically reduce the chance of nuisance alarms. The intelligent sensor technology combines the detection capabilities of an ionization smoke sensor - which is more likely to detect smaller, less visible fire particles, like those produced by flaming fires - with that of an electrochemical sensor, which is used to detect CO. Since carbon monoxide is present in all fires, having both detection chambers work together in one alarm is a breakthrough in the fire safety industry. When either sensor notices a potential hazard, it will communicate with the other. Depending on what is detected, the alarm will adjust its smoke sensitivity in order to better discriminate between a real hazard and a false one. This constant communication enhances the alarm overall performance in all fires and significantly reduces the potential for a nuisance alarm. Leading authorities recommend that both ionization and photoelectric smoke alarms be installed to help insure maximum detection of the various types of fires that can occur within the home. Ionization sensing alarms may detect invisible fire particles (associated with fast flaming fires) sooner than photoelectric alarms. Photoelectric sensing alarms may detect visible fire particles (associated with slow smoldering fires) sooner than ionization alarms.

Product Details

Kidde® Talking Smoke and Carbon Monoxide Alarm, 1-Button Combination Multi-Function, (2) AA Batteries Power Source, 10 ft Detection, Electrochemical/Ionization Sensor, 24 Kidde® Devices Interconnection, 85 dB at 10 ft Alert, Fire/Warning Carbon Monoxide/Low Battery Visual Alert, 10 to 95 % Humidity, 2 Sensors, Quick-Connect Plug with 6 in Pigtail Wiring, 40 to 100 deg F Operating, 12.3 cm Dia x 3.2 cm D Dimensions

The Kidde® KN-COSM-IBACA uses breakthrough technology to offer a fast response to real fires, including smoldering and fast flaming, as well as protect you from carbon monoxide and dramatically reduce the chance of nuisance alarms. The intelligent sensor technology combines the detection capabilities of an ionization smoke sensor - which is more likely to detect smaller, less visible fire particles, like those produced by flaming fires - with that of an electrochemical sensor, which is used to detect CO. Since carbon monoxide is present in all fires, having both detection chambers work together in one alarm is a breakthrough in the fire safety industry. When either sensor notices a potential hazard, it will communicate with the other. Depending on what is detected, the alarm will adjust its smoke sensitivity in order to better discriminate between a real hazard and a false one. This constant communication enhances the alarm overall performance in all fires and significantly reduces the potential for a nuisance alarm. Leading authorities recommend that both ionization and photoelectric smoke alarms be installed to help insure maximum detection of the various types of fires that can occur within the home. Ionization sensing alarms may detect invisible fire particles (associated with fast flaming fires) sooner than photoelectric alarms. Photoelectric sensing alarms may detect visible fire particles (associated with slow smoldering fires) sooner than ionization alarms.

Attributes

Audible Alert85 dB at 10 ft
Clearance ItemsClearance
Detection Range10 ft
Dimensions12.3 cm Dia x 3.2 cm D
Humidity Rating10 to 95 %
Interconnection Capability24 Kidde® Devices
Number of Sensors2
Operating Temperature40 to 100 deg F
Power Source(2) AA Batteries
Sensor TypeElectrochemical/Ionization
Type1-Button Combination Multi-Function
Visual AlertFire/Warning Carbon Monoxide/Low Battery
Wiring TypeQuick-Connect Plug with 6 in Pigtail

Features

  • Combined carbon monoxide and smoke alarm, a single unit can be installed where previously, two were needed
  • Reduces installation time and protects against both fire and carbon monoxide dangers
  • Intelligent sensor Technology™ combines the detection capabilities of an ionization smoke sensor with that of an electrochemical carbon monoxide sensor
  • When either sensor notices a potential hazard, the alarm will adjust its smoke sensitivity to differentiate between a real hazard and a false one
  • Voice warning announces the hazard type detected (in English and French)
  • Alarm announces fire when a smoke or fire hazard is detected and announces warning carbon monoxide when a carbon monoxide hazard is detected
  • Also announces low battery when it is time to replace the batteries
  • 120 VAC interconnectable will interconnect with up to 24 other devices (18 of which can be initiating), including smoke alarms (limit of 12), carbon monoxide and heat alarms
  • AA front loading battery backup, change batteries without the need to remove the unit from the ceiling, providing continuous protection in the case of a power outage
  • Tamper-resistant unit will lock to mounting bracket to deter theft or tampering
  • End of life notification 10 years after unit is first powered, this alarm will beep two times every 30 s to indicate it is time to replace the alarm
  • Alarm memory, the green LED will flash every second during alarm
  • When the alarm condition goes away, the originating alarm unit will flash the green LED every 16 s until the test/reset button is pressed, thus resetting the alarm
  • Test feature tests the alarm circuitry and triggers the voice announcement
  • Hush® feature temporarily silences nuisance alarms for approximately 9 min (will announce "Hush mode Activated" or "Hush mode Cancelled")
  • Reset feature resets the carbon monoxide alarm
  • Peak level memory if alarm has detected a carbon monoxide level of 100 ppm or higher since it was last reset, the voice alarm will announce Caution, carbon monoxide previously Detected