content loaded
MACROMATIC ISEUR1 Image 1

MACROMATIC ISEUR1 DIN MOUNT 1 CHANNEL 102-132V AC & 10-125V DC 5A NO INTRINSICALLY SAFE RELAY

MFR Part #: ISEUR1
SKU #: 1264748
Brand: MACROMATIC
UPC: 400051091956
MACROMATIC ISEUR1 Intrinsically Safe Relay; DIN Mount; One Channel; 102-132V AC & 10-125V DC; 5A NO
UL Listed (cULus, File #E318075) | CE Marked

MACROMATIC ISEUR1 Intrinsically Safe Relay, ISE Series, Mechanical Life of 5000000 closures, Operating Temp of -28 to 60 deg C, Storage Temp of -55 to 85 deg C, Panel-mounted or DIN-Rail Mounting, 102-132V AC (50/60 Hz) and 10-125V DC Control Voltage, 2 VA Load

Each ISE Series relay consists of an intrinsically safe input and a corresponding electromechanical relay output. There is one bi-color LED for status indication. With input voltage applied, the LED will be ON (GREEN) to indicate power is applied. Standard Operation When the input device from the hazardous area is closed, the output relay is energized and the LED is ON (ORANGE). When the input device opens, the output relay will de-energize and the LED will be ON (GREEN). Inverted Operation (V-suffix) When the input device from the hazardous area is open, the output relay is energized and the LED is ON (ORANGE). When the input device closes, the output relay will be de-energized and the LED will be ON (GREEN).

Product Details

MACROMATIC ISEUR1 Intrinsically Safe Relay, ISE Series, Mechanical Life of 5000000 closures, Operating Temp of -28 to 60 deg C, Storage Temp of -55 to 85 deg C, Panel-mounted or DIN-Rail Mounting, 102-132V AC (50/60 Hz) and 10-125V DC Control Voltage, 2 VA Load

Each ISE Series relay consists of an intrinsically safe input and a corresponding electromechanical relay output. There is one bi-color LED for status indication. With input voltage applied, the LED will be ON (GREEN) to indicate power is applied. Standard Operation When the input device from the hazardous area is closed, the output relay is energized and the LED is ON (ORANGE). When the input device opens, the output relay will de-energize and the LED will be ON (GREEN). Inverted Operation (V-suffix) When the input device from the hazardous area is open, the output relay is energized and the LED is ON (ORANGE). When the input device closes, the output relay will be de-energized and the LED will be ON (GREEN).

Attributes

Control Voltage102-132V AC (50/60 Hz) and 10-125V DC
Load2 VA
Mechanical Life5000000 closures
Mounting TypePanel-mounted or DIN-Rail
Operating Temperature-28 to 60 deg C
SeriesISE Series
Storage Temperature-55 to 85 deg C

Features

  • Approved for use in Class I, Class II, and Class III Hazardous Locations (Zones 0 & 1 in Canada)
  • 1-Channel
  • 5A relay output
  • Universal input voltage of 102-132V AC & 10-125V DC
  • LED status indicator