ABB Lighting Contactor, 100 to 250 V AC/DC Coil, 45 A Maximum Load Current, 5.5 kW, 11 kW, 9 kW Coil, 4 Pole, 50/60 Hz Frequency, 4NO Contact Configuration, 600 VAC Contact, AF26 Size, Double Connector Screw Terminal, IP20 Enclosure, 10000000 Cycles Operating Cycles, -40 to 70 deg C Operating, 101 mm L x 45 mm W x 86 mm H Dimensions
AF26 contactors are used for controlling power circuits up to 690 VAC and 220 VDC. They are mainly used for controlling 3-phase motors, non-inductive or slightly inductive loads. AF contactors include an electronic coil interface accepting a wide control voltage Uc min to Uc max. Only four coils cover control voltages between 24 to 500 VAC 50/60 Hz or 20 to 500 VDC. AF contactors can manage large control voltage variations. One coil can be used for different control voltages used worldwide without any coil change. AF contactors have built-in surge protection and do not require additional surge suppressors. The AF series 1-stack 3-pole contactors are of the block type design. Main poles and auxiliary contact blocks: 3 main poles, front and side-mounted add-on auxiliary contact blocks (mechanically linked auxiliary contacts compliant with Annex L of IEC 60947-5-1. NC mirror contacts compliant with Annex F of IEC 60947-4-1), control circuit: AC or DC operated, Accessories: a wide range of accessories is available.
ABB Lighting Contactor, 100 to 250 V AC/DC Coil, 45 A Maximum Load Current, 5.5 kW, 11 kW, 9 kW Coil, 4 Pole, 50/60 Hz Frequency, 4NO Contact Configuration, 600 VAC Contact, AF26 Size, Double Connector Screw Terminal, IP20 Enclosure, 10000000 Cycles Operating Cycles, -40 to 70 deg C Operating, 101 mm L x 45 mm W x 86 mm H Dimensions
AF26 contactors are used for controlling power circuits up to 690 VAC and 220 VDC. They are mainly used for controlling 3-phase motors, non-inductive or slightly inductive loads. AF contactors include an electronic coil interface accepting a wide control voltage Uc min to Uc max. Only four coils cover control voltages between 24 to 500 VAC 50/60 Hz or 20 to 500 VDC. AF contactors can manage large control voltage variations. One coil can be used for different control voltages used worldwide without any coil change. AF contactors have built-in surge protection and do not require additional surge suppressors. The AF series 1-stack 3-pole contactors are of the block type design. Main poles and auxiliary contact blocks: 3 main poles, front and side-mounted add-on auxiliary contact blocks (mechanically linked auxiliary contacts compliant with Annex L of IEC 60947-5-1. NC mirror contacts compliant with Annex F of IEC 60947-4-1), control circuit: AC or DC operated, Accessories: a wide range of accessories is available.